CUMMINS DIESEL GENERATOR SET
Reliable, rugged, durable design
Field-proven in thousands of applications worldwide
Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
Factory Tested To Design Specifications At 110% Load Conditions
Specification of 200kVA Cummins Diesel Generator Set:
Model | A-C220 | |
Max. Power | kVA | 220 |
kW | 176 | |
Rate Power | kVA | 200 |
kW | 160 | |
Frequency | Hz | 50 |
Rate Voltage | V | 400/230 |
Rate Current | A | 288.7 |
Fuel Tank Capacity | L | 235 |
Dimension For Open-type Genset | mm | 2654 X 1156 X 1595 |
Weight For Open-type Genset | kg | 1600 |
Dimension For Soundproof Genset | mm | 3500 X 1126 X 1700 |
Weight For Soundproof Generator | kg | 2400 |
Noise Level for Soundproof Generator at 7M | dBA | 80 |
Battery | Two of 100Amps Free Maintenance Battery |
ALTERNATOR
Use one of the most famous brand alternator with Leroy Somer brand
Matched to the performance and output characteristics of engines
Industry leading mechanical and electrical design
Industry leading motor starting capabilities
High Efficiency
IP23 Protection
Specification of Leroy Somer Brushless Alternator:
Alternator Manufacturer | Leroy Somer | |
Alternator Model | TAL-A46-B | |
Alternator Brand | Leroy Somer | |
Rate Output | kVA | 200 |
Frequency | Hz | 50Hz |
Altitude | M | ≤1000 |
Insulation | Class H | |
Automatic Voltage Regulation | SX440 | |
Protection Grade | IP23 | |
Alternator for optional | Stamford, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
Specification of Control Panel:
Control Panel Model | AF500 |
Controller | Deepsea Brand Model DSE7320 |
Function of control panel | Automatic genset start/stop |
Automatic battery charger | |
Emergency stop | |
AMF (Automatic Mains Fault) | |
Remote control | |
Micro-processor based design | |
LED alarm indication and Sound alarm | |
Display of the controller | Generator voltage: Uab, Ubc, Uca |
Generator current: Ua, Ub, Uc | |
Generator temp.: ℃/℉ both display | |
Generator frequency: Hz | |
Generator power: kW, kVA, kWh, kVAr, kVArh, kVAh | |
Generator starts count: 999999 times (Max) | |
Generator pressure: kPa/Psi/Bar both display | |
Charging Voltage: V | |
Battery Voltage: V DC | |
Protection of Diesel Generator | Over / Under Speed Alarm and Shutdown |
Start / Stop Failure Alarm | |
Over Current Alarm and Shutdown | |
Under / Over Generator Voltage Alarm and Shutdown | |
Low Oil Pressure Alarm and Shutdown | |
High Engine Temperature Alarm and Shutdown | |
Over Load Alarm and Shutdown | |
Low and High Battery Voltage Alarm | |
Lose of Speed Signal Alarm and Shutdown | |
Charge Fail Alarm |
DESIGN CRITERIA:
The generator set is designed to meet ISO8528-5 transient response and NFPA 110.
Cooling system designed to operate in 50˚C / 122˚F ambient temperatures with an air flow restriction of 0.5 in. water