Datasheet of 65kVA Silent Perkins Diesel Generator Set:
Model | A-P71 | |
Max. Power | kVA | 71 |
kW | 57.2 | |
Rate Power | kVA | 66 |
kW | 52.8 | |
Frequency | Hz | 50 |
Rate Voltage | V | 400/230 |
Rate Current | A | 95.3 |
Fuel Tank Capacity | L | 100 |
Dimension For Open-type Genset | mm | 1860 X 750 X 1200 |
Weight For Open-type Genset | kg | 978 |
Dimension For Soundproof Genset | mm | 2300 X 900 X 1250 |
Weight For Soundproof Generator | kg | 1350 |
Noise Level for Soundproof Generator at 7M | dBA | 65 |
Battery for Starting | One of 80A Free Maintenance Battery |
Datesheet of Perkins Diesel Engine:
Engine Manufacturer | Perkins | |
Engine Brand | Perkins | |
Engine Model | 1104A-44TG1 | |
No. of Cylinder | 4 Cylinder in line | |
Aspiration | Turbocharged | |
Governor | Mechanical | |
Engine Max. Output Power | kW | 65.6 |
Displacement | L | 4.4 |
Compression Ratio | 17.25 : 1 | |
Starting Voltage | V | 12 |
Bore | mm | 105 |
Stroke | mm | 127 |
Lubrication Oil Capacity | L | 7 |
Intake Air Flow | M3/Min | 4 |
Fuel Consumption at 100% Load | L/H | 14.8 |
Datasheet of Stamford Alternator:
Alternator Manufacturer | Cummins Generator Technologies | |
Alternator Model | UCI 224 F | |
Alternator Brand | Stamford | |
Rate Output | kVA | 72 |
Frequency | Hz | 50Hz |
Altitude | M | ≤1000 |
Insulation | Class H | |
Phase | 3 Phase | |
Working Temperature without power decrease | ≤40℃ | |
Working Altitude without power decrease | ≤1000m | |
Automatic Voltage Regulation | SX460 | |
Protection Grade | IP23 | |
Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
Control Panel of Perkins Diesel Generator:
Controller Brand | Deepsea | |
Controller Model | DSE7320 | |
Breaker Brand | Delixi | |
Breaker Capacity (A) | 125 | |
Battery Charger | Smartgen Model BAC06A | |
Emergency Stop Button | Supply | |
Automatic Mains Fail (AMF) | Supply | |
Fuel Level | Supply | |
Automatic Transfer Switch | ATS as optional part | |
The control panel supply the full protection with alarm and shutdown of the diesel generator include Start-up fault (generator set shutdown), High coolant temperature (alarm and generator set shutdown), Low oil pressure (alarm and generator set shutdown), Low fuel level (alarm), Low cooling fluid level alarm (as optional), Overload (alarm and generator set shutdown), Battery voltage high (alarm). | ||
Optional controller: Each model of Deepsea, Smartgen, ComAp brand controller. |
Features of Hosem Power Diesel Generator:
1. Hosem Power supply the diesel generator with CE certificate, ISO9001-2005 certificate, and the diesel generator produce according the ISO8528 international standard.
2. Hosem Power supply rated output from 3kVA to 3000kVA with Open-type diesel generator set, silent diesel generator set, mobile diesel generator set for client optional. The silent diesel generator with waterproof at IP44 standard.
3. Each the offered prime output are no problem for continue running, and each generator set has the ability to run with 110% of prime output for 1hour at each 12hours.
4. The design of the diesel generator can be customized made as client's requirements.