Technical Data of 50kVA Super Silent Generator Set:
Model | A-P50 | |
Max. Power | kVA | 50 |
kW | 39.6 | |
Rate Power | kVA | 45 |
kW | 36 | |
Frequency | Hz | 50 |
Rate Voltage | V | 400/230 |
Rate Current | A | 65.0 |
Fuel Tank Capacity | L | 60 |
Dimension For Open-type Genset | mm | 1560 X 750 X 1200 |
Weight For Open-type Genset | kg | 870 |
Dimension For Soundproof Genset | mm | 2300 X 900 X 1250 |
Weight For Soundproof Generator | kg | 1226 |
Noise Level for Soundproof Generator at 7M | dBA | 72 |
Battery for Starting | Two of Free Maintenance Battery |
Technical Data of Perkins Diesel Engine:
Engine Manufacturer | Perkins | |
Engine Brand | Perkins | |
Engine Model | 1103A-33TG1 | |
No. of Cylinder | 3 Cylinder in line | |
Aspiration | Turbocharged | |
Governor | Electric | |
Engine Max. Output Power | kW | 46.5 |
Displacement | L | 3.3 |
Compression Ratio | 17.25 : 1 | |
Starting Voltage | V | 24 |
Bore | mm | 105 |
Stroke | mm | 127 |
Lubrication Oil Capacity | L | 7.8 |
Intake Air Flow | M3/Min | 2.9 |
Fuel Consumption at 100% Load | L/H | 10.7 |
Technical Data of Stamford Alternator:
Alternator Manufacturer | Cummins Generator Technologies | |
Alternator Model | UCI 224 D | |
Alternator Brand | Stamford | |
Rate Output | kVA | 50 |
Frequency | Hz | 50Hz |
Altitude | M | ≤1000 |
Insulation | Class H | |
Phase | 3 Phase | |
Working Temperature without power decrease | ≤40℃ | |
Working Altitude without power decrease | ≤1000m | |
Automatic Voltage Regulation | SX460 | |
Protection Grade | IP23 | |
Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
Technical Data of Control Panel:
Controller Brand | Deepsea | |
Controller Model | DSE7320 | |
Breaker Brand | Delixi | |
Breaker Capacity (A) | 80 | |
Battery Charger | Smartgen Model BAC06A | |
Emergency Stop Button | Supply | |
Automatic Mains Fail (AMF) | Supply | |
Fuel Level | Supply | |
Automatic Transfer Switch | ATS as optional part | |
The control panel supply the full protection with alarm and shutdown of the diesel generator include Start-up fault (generator set shutdown), High coolant temperature (alarm and generator set shutdown), Low oil pressure (alarm and generator set shutdown), Low fuel level (alarm), Low cooling fluid level alarm (as optional), Overload (alarm and generator set shutdown), Battery voltage high (alarm). | ||
Optional controller: Each model of Deepsea, Smartgen, ComAp brand controller. |
Features:
1. Use the Deepsea brand model DSE7320 AMF controller for the 50kVA super silent generator set. The controller will automatic controller the diesel generator start and stop, and it will monitor the mains power for control the diesel generator start and stop.
2. Use the Stamford alternator model UCI 224 D alternator produced by Cummins Generator Technologies with automatic voltage regulation.
3. Supply 10kVA to 2450kVA Perkins diesel generator set for client's choice, it can meet most of the client's requirements.
4. Supply open type diesel generator, soundproof diesel generator and trailer diesel generator to meet each kinds of the users.