Specification:
Model | A-C853H | |
Standby Power | kVA | 853 |
kW | 682 | |
Prime Power | kVA | 775 |
kW | 620 | |
Frequency | Hz | 60 |
Output Voltage | V | 240 |
Oil Consumption | L/H | 0.500640861 |
Dimension For Open-type | mm | 4243 X 1820 X 2323 |
Weight For Open-type | kg | 6058 X 2438 X 2591 |
Dimension For Soundproof | mm | 85 |
Weight For Soundprof | kg | 3832 |
Engine Model | KT38-G | |
No.of Cylinder | 12 Cylinder V Type | |
Bore | mm | 159 |
Stroke | mm | 159 |
Displacement | L | 37.8 |
Cooling Fan Air Flow | m3/min | 1825 |
Compress Air Flow | m3/min | 55.2 |
Exhaust Gas Flow | m3/min | 158.6 |
Exhaust Gas Temperature | ℃ | 552 |
Lubrication Oil Capacity | L | 135 |
Cooling Water Capacity | L | 194 |
Starting Voltage | V | 24 |
Engine Max.Output Power | kW | 747 |
Alternator Model | HCI 544 F-S | |
Alternator Brand | Stamford | |
Rate Output | kVA | 775 |
Frequency | Hz | 60 |
Altitude | M | ≤1000 |
Insulation | Class H | |
Protection Grade | IP23 | |
Alternator for choice | We also have Leroy Somer, Marathon, Mecc Alte and Chinese brand Brushless alternator for your choice. | |
Control Panel Model | AF500 | |
Controller | Deepsea Brand Model DSE7320 | |
Function of control panel | Automatic genset start/stop | |
Automatic battery charger | ||
Emergency stop | ||
AMF (Automatic Mains Fault) | ||
Remote control | ||
Micro-processor based design | ||
LED alarm indication and Sound alarm | ||
Display of the controller | Generator voltage: Uab, Ubc, Uca | |
Generator current: Ua, Ub, Uc | ||
Generator temp.: ℃/℉ both display | ||
Generator frequency: Hz | ||
Generator power: kW, kVA, kWh, kVAr, kVArh, kVAh | ||
Generator starts count: 999999 times (Max) | ||
Generator pressure: kPa/Psi/Bar both display | ||
Charging Voltage: V | ||
Battery Voltage: V DC | ||
Protection of Diesel Generator | Over / Under Speed Alarm and Shutdown | |
Start / Stop Failure Alarm | ||
Over Current Alarm and Shutdown | ||
Under / Over Generator Voltage Alarm and Shutdown | ||
Low Oil Pressure Alarm and Shutdown | ||
High Engine Temperature Alarm and Shutdown | ||
Over Load Alarm and Shutdown | ||
Low and High Battery Voltage Alarm | ||
Lose of Speed Signal Alarm and Shutdown | ||
Charge Fail Alarm |
Product features:
Good sound insulation effect, 80dBA at 7 meters.
Side doors are mounted on both sides, convenient for daily check and maintenance.
External oil filter design can ensure fuel safety when generating sets outside.
Cabinet and base frame are made of high-quality slabs and coated with excellent coating material, with three layers of bottom-medium-top spraying process and high anti-corrosion and antirust capacity.
Application scope:
It is applied in various construction sites, such as huge buildings, airports, harbors, offshore operation platforms and field projects, etc.
Why Choose Hosem Power Generator?
Reasons1: We are More Professional
Most members of Hosem Power have more than 10 years of experience in the generator area, Our mechanical engineers, electrical engineers have more than 20 years of experience in the generator ara. We are always ready to serve to your needs.
Reasons2: Outstanding Quality
Our advantage lies in:
1. Good shock absorption performance: Optimal design of shock absorption system based on computer dynamic simulation.
2. Advanced control system: Full monitoring system control strategy found on reliability design.
3. Low noise: Tailor custom-engineered exhaust silencer system for each set.
4. Green environmental protection: Diesel generator set combined energy-saving and low emission in one.
Reasons3: Strictly QC Before EX-Factory.
Each and every unit is strictly factory tested before shipment.
1) Parts faults testing
2) Fuel tank pressure testing
3) Bolt tightening torque testing
4) Painting thickness testing
5) Voltage bearing and insulation testing
6) Noise testing
7) Loading Testing: 25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection.