Products Name: A.C. Generator
Rated Output: 20kVA / 16kW
Voltage: 110-690V For Optional
Frequency: 50Hz
Voltage Regulation: +-1%
Power Factor: 0.8 Lagging
Protection: IP23
Insulation: Class H
Speed: 1500RPM
Phase: Three Phase
Bearing: Single Bearing With SAE No.
Highlight:

20kva ac synchronous generator

,

16kw ac synchronous generator

,

three phase ac synchronous generator

Basic Infomation
Place of Origin: Fuzhou, China.
Brand Name: Hosem
Certification: CE, ISO9001, ISO14001
Model Number: ASF184ES
Payment & Shipping Terms
Packaging Details: Plywood Packing
Delivery Time: 25 Days
Supply Ability: 2000 Sets Per Month
Product Description

AC Generator 20kVA 16kW 50Hz 1500RPM Three Phase for Industrial

SPECIFICATIONS & OPTIONS

STANDARDS
1. Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.
2. Other standards and certifications can be considered on request.

 

VOLTAGE REGULATOR
AS480 AVR fitted as STANDARD
1. With this self-excited system the main stator provides power via the AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage.
2. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-of-phase paralleling. The AS480 will support limited accessories, RFI suppession remote voltage trimmer and for the P1 range only a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators.
3. The AVR is can be fitted to either side of the generator in its own housing in the non-drive end bracket.

 

Excitation Boost System (EBS) (OPTIONAL)
1. The EBS is a single, self-contained unit, attached to the non-drive end of the generator.
2. The EBS unit consists of the Excitation Boost Controller (EBC) and an Excitation Boost Generator (EBG). Under fault conditions, or when the generator is subjected to a large impact load such as a motor starting, the generator voltage will drop. The EBC senses the drop in voltage and engages the output power of the EBG. This additional power feeds the generator’s excitation system, supporting the load until breaker discrimination can remove the fault or enable the generator to pick up a motor and drive the voltage recovery.

 

AC Generator 20kVA 16kW 50Hz 1500RPM Three Phase for Industrial

 

WINDINGS & ELECTRICAL PERFORMANCE
All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th …) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion.

TERMINALS & TERMINAL BOX
Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted at the non-drive end of the generator. Dedicated single phase generators are also available. A sheet steel terminal box contains provides ample space for the customers' wiring and gland arrangements. Alternative terminal boxes are available for customers who want to fit additional components in the terminal box.

 

SHAFT & KEYS
All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key.

 

INSULATION / IMPREGNATION
1. The insulation system is class 'H'.
2. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components.

AC Generator 20kVA 16kW 50Hz 1500RPM Three Phase for Industrial

 

QUALITY ASSURANCE
1. Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001.
2. The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%.

 

DE RATES
1. All values tabulated on page 9 are subject to the following reductions
2. 5% when air inlet filters are fitted.
3. 3% for every 500 metres by which the operating altitude exceeds 1000 metres above mean sea level.
4. 3% for every 5°C by which the operational ambient temperature exceeds 40°C.
5. Requirement for operating in an ambient exceeding 60°C must be referred to the factory.

 

5% For reverse rotation
(Standard rotation CW when viewed from DE)
NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding.

AC Generator 20kVA 16kW 50Hz 1500RPM Three Phase for Industrial

ASF 184 ES 20KVA BRUSHLESS ALTERNATOR SPECIFICATION (WINDING 311)
CONTROL SYSTEM STANDARD AS480 AVR (SELF EXCITED)
VOLTAGE REGULATION ± 1.0 %
SUSTAINED SHORT CIRCUIT SELF EXCITED MACHINES DO NOT SUSTAIN A SHORT CIRCUIT CURRENT
CONTROL SYSTEM AS480 AVR WITH OPTIONAL EXCITATION BOOST SYSTEM (EBS)
SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVE
 
STATOR WINDING DOUBLE LAYER CONCENTRIC
WINDING PITCH TWO THIRDS
WINDING LEADS 12
STATOR WDG. RESISTANCE 0.377 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED
ROTOR WDG. RESISTANCE 0.657 Ohms at 22°C
EXCITER STATOR RESISTANCE 18.5 Ohms at 22°C
EXCITER ROTOR RESISTANCE 0.228 Ohms PER PHASE AT 22°C
EBS STATOR RESISTANCE 12.9 Ohms at 22°C
R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others
WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%
MAXIMUM OVERSPEED 2250 Rev/Min
BEARING DRIVE END BALL. 6309 - 2RS. (ISO)
BEARING NON-DRIVE END BALL. 6306 - 2RS. (ISO)
  1 BEARING 2 BEARING
  WITH EBS WITHOUT EBS WITH EBS WITHOUT EBS
WEIGHT COMP. GENERATOR 120.5 kg 118.8 kg 123.5 kg 121.8 kg
WEIGHT WOUND STATOR 44 kg 44 kg 44 kg 44 kg
WEIGHT WOUND ROTOR 41.87 kg 40.17 kg 42.87 kg 41.17 kg
WR² INERTIA 0.156 kgm2 0.1544 kgm2 0.1562 kgm2 0.1545 kgm2
SHIPPING WEIGHTS in a crate 138 kg 136.3 kg 147 kg 145.3 kg
PACKING CRATE SIZE 71 x 51 x 67 (cm) 71 x 51 x 67 (cm)
  50 Hz 60 Hz
TELEPHONE INTERFERENCE THF<2% TIF<50
COOLING AIR 0.100 m³/sec 212cfm 0.122 m³/sec 251 cfm
VOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277
VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138
VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138
kVA BASE RATING FOR REACTANCE VALUES                
20 20 20 19 22 23.5 24.3 25
Xd DIR. AXIS SYNCHRONOUS 1.66 1.5 1.39 1.18 1.97 1.88 1.78 1.68
X'd DIR. AXIS TRANSIENT 0.17 0.15 0.14 0.12 0.2 0.19 0.18 0.17
X''d DIR. AXIS SUBTRANSIENT 0.11 0.1 0.09 0.08 0.13 0.12 0.12 0.11
Xq QUAD. AXIS REACTANCE 0.8 0.72 0.67 0.57 0.95 0.91 0.86 0.81
X''q QUAD. AXIS SUBTRANSIENT 0.18 0.16 0.15 0.13 0.21 0.2 0.19 0.18
XL LEAKAGE REACTANCE 0.07 0.06 0.06 0.05 0.08 0.08 0.07 0.07
X2 NEGATIVE SEQUENCE 0.14 0.13 0.12 0.1 0.17 0.16 0.15 0.15
X0 ZERO SEQUENCE 0.07 0.06 0.06 0.05 0.08 0.08 0.07 0.07
REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED
T'd TRANSIENT TIME CONST. 0.017 s
T''d SUB-TRANSTIME CONST. 0.004 s
T'do O.C. FIELD TIME CONST. 0.38 s
Ta ARMATURE TIME CONST. 0.007 s
SHORT CIRCUIT RATIO 1/Xd

 

AC Generator 20kVA 16kW 50Hz 1500RPM Three Phase for Industrial

ASF 184ES 20KVA A.C. Brushless Alternator Ratings 50Hz 0.8 Power Factor Winding 311
Class - Temp Rise Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C
Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440
Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220
Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254
kVA 18.2 18.2 18.2 17.3 20 20 20 19 21.5 21.5 21.5 20.4 22 22 22 20.9
kW 14.6 14.6 14.6 13.8 16 16 16 15.2 17.2 17.2 17.2 16.3 17.6 17.6 17.6 16.7
Efficiency (%) 85.4 85.7 85.8 86 84.8 85.1 85.3 85.7 84.2 84.6 84.8 85.4 84 84.4 84.6 85.2
kW Input 17 17 17 16.1 18.9 18.8 18.8 17.7 20.4 20.3 20.3 19.1 21 20.9 20.8 19.6

 

 