Generator Set Specification | ||
Model | A-DE28HS | |
Max. Power | kVA | 28 |
kW | 22.4 | |
Rate Power | kVA | 25 |
kW | 20 | |
Frequency | Hz | 60 |
Rate Voltage | V | 220/127 |
Rate Current | A | 65.6 |
Dimension For Open-type Genset | mm | 1650 X 700 X 1250 |
Weight For Open-type Genset | kg | 620 |
Dimension For Soundproof Genset | mm | 2000 X 900 X 1250 |
Weight For Soundproof Generator | kg | 870 |
Engine Specification | ||
Engine Manufacturer | Deutz (Dalian) Engine Co., Ltd. | |
Engine Brand | Deutz | |
Engine Model | BFM3 G1 | |
No. of Cylinder | 4 Cylinder in line | |
Aspiration | Naturally aspirated | |
Governor | Electric | |
Engine Max. Output Power | kW | 25 |
Displacement | L | 3.2 |
Starting Voltage | V | 12 |
Bore | mm | 98 |
Stroke | mm | 105 |
Lubrication Oil Capacity | L | 7.5 |
Alternator Specification | ||
Alternator Manufacturer | Cummins Generator Technologies | |
Alternator Model | PI 144D | |
Alternator Brand | Stamford | |
Rate Output | kVA | 20 |
Frequency | Hz | 60Hz |
Altitude | M | ≤1000 |
Insulation | Class H | |
Voltage Regulation | AVR Model SX460 | |
Protection Grade | IP23 | |
Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
Control Panel Specification | ||
Controller Brand | Smartgen | |
Controller Model | HGM 6120N | |
Breaker Brand | Delixi | |
Breaker Capacity | 80A | |
Battery Charger | Supply | |
Emergency Stop Button | Supply | |
Automatic Mains Fail (AMF) | Supply | |
The control panel supply the full protection with Alarm and Shutdown of the diesel generator include High Temp, Low Oil Pressure, Over / Under Speed, Over Load, Start / Stop Fail, Under / Over Voltage etc. | ||
Optional controller: Each model of Deepsea, Smartgen, ComAp brand controller. |
Product Description
Δ Main Features
Δ Testing Items
Hosem Power provides a full line of brand-new and high-quality products.
Each and every unit is strictly factory tested before shipment.
1) Parts faults testing
2) Fuel tank pressure testing
3) Bolt tightening torque testing
4) Painting thickness testing
5) Voltage bearing and insulation testing
6) Noise testing
7) Loading Testing(25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection)
Δ FAQ
Q1: Can you accept OEM orders?
A: Yes, we have a professional design team and sincerely welcome OEM orders.
Q2: Which trade term can you accept?
A: Available trade terms: FOB, CIF, CFR, EXW, etc.
Q3: What is your company's available production capacity?
A:100 Sets per month.
Q4: What is the power range of your diesel generator?
A: We can provide power from 0.7kVA-2000kVA.