Generator Set Specification | ||
Model | A-SH250S | |
Max. Power | kVA | 250.0 |
kW | 200.0 | |
Rate Power | kVA | 225.0 |
kW | 180.0 | |
Frequency | Hz | 50 |
Rate Voltage | V | 400/230 |
Rate Current | A | 324.8 |
Dimension For Open-type Genset | mm | 2550 X 990 X 1650 |
Weight For Open-type Genset | kg | 1870 |
Dimension For Soundproof Genset | mm | 3500X 1200 X 1800 |
Weight For Soundproof Generator | kg | 2500 |
Noise Level at 7 Meters | dBA | 75 |
Fuel Tank Capacity | Liters | 280 |
Battery | Two of Free Maintenance Battery |
Engine Specification | ||
Engine Manufacturer | Shanghai Diesel Engine Co., Ltd. | |
Engine Brand | SDEC | |
Engine Model | SC9D310D2 | |
No. of Cylinder | 6 Cylinder in line | |
Aspiration | Turbocharged and Air to Air Aftercooled | |
Governor | Electric | |
Engine Max. Output Power | kW | 228 |
Displacement | L | 8.280 |
Starting Voltage | V | 24 |
Bore | mm | 114 |
Stroke | mm | 144 |
Lubrication Oil Capacity | L | 22 |
Compression Ratio | 18 : 1 | |
Intake Air Flow | M3/Min | 16.4 |
Fuel Consumption at 100% Load | L/H | 50.6 |
Alternator Specification | ||
Alternator Manufacturer | Fuzhou Hosem Power Co., Ltd. | |
Alternator Model | ASF274J | |
Alternator Brand | Hosem | |
Rate Output | kVA | 225 |
Frequency | Hz | 50Hz |
Current | A | 324.8 |
Insulation | Class H | |
Voltage Regulation | SX440 | |
Protection Grade | IP23 | |
Working Temperature without Output Decrease | ≤1000m | |
Phase | 3 Phase | |
Temperature Rise | 125 Degree Celsius | |
Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
Control Panel Specification | ||
Controller Brand | Deepsea | |
Controller Model | DSE7320 | |
Breaker Brand | Delixi | |
Breaker Capacity | A | 400 |
Battery Charger | Smartgen Model BAC06A | |
Emergency Stop Button | Supply | |
Automatic Mains Fail (AMF) | Supply | |
Fuel Level | Supply | |
Automatic Transfer Switch | ATS as optional part | |
Mains Monitor | Supply with AMF Function | |
The control panel supply the full protection with alarm and shutdown of the diesel generator include Start-up fault (generator set shutdown), High coolant temperature (alarm and generator set shutdown), Low oil pressure (alarm and generator set shutdown), Low fuel level (alarm), Low cooling fluid level alarm (as optional), Overload (alarm and generator set shutdown), Battery voltage high (alarm). | ||
Optional controller: Each model of Deepsea, Smartgen, ComAp brand controller. |
Choose Hosem Power Diesel Generator for a dependable, mobile power solution that delivers exceptional performance and ease of use. Contact us today to learn more!