30kVA Perkins Generator Set with Stamford Alternator and 1103A-33G Engine for Reliable Power
The 30kVA Perkins Generator Set powered by the 1103A-33G engine and matched with a genuine Stamford alternator is designed to deliver dependable, efficient, and stable power for a wide range of applications. Combining the globally trusted Perkins diesel engine with the proven performance of a Stamford alternator, this generator set ensures excellent voltage stability, smooth load response, and long-term operational reliability.
The Perkins 1103A-33G engine is well known for its fuel efficiency, low emissions, and robust construction, making it an ideal choice for both prime power and standby power use. Paired with a Stamford alternator featuring high-quality AVR regulation, this 30kVA generator delivers clean, consistent electricity suitable for sensitive electrical equipment.
Manufactured under strict quality control standards, the generator set is factory-tested before delivery and built to perform reliably in industrial, commercial, and residential environments.
Trusted Perkins 1103A-33G Engine
lRated output: 30kVA / 24kW
lProven durability with long service life
Genuine Stamford Alternator
lHigh-efficiency alternator with stable voltage output
lSuperior insulation and winding design for reliable performance
lIdeal for sensitive loads and continuous operation
Stable & User-Friendly Operation
lAdvanced digital control panel with full monitoring and protection
lAutomatic alarms and shutdown for engine and electrical safety
lOptional ATS for automatic power transfer
Durable Construction
lHeavy-duty steel base frame with anti-vibration mounts
lCompact layout for easy installation and servicing
lDesigned for long-term operation in demanding conditions
| Generator Set Specification | ||
| Model | A-P33S | |
| Max. Power | kVA | 33 |
| kW | 26.4 | |
| Rate Power | kVA | 30 |
| kW | 24 | |
| Frequency | Hz | 50 |
| Rate Voltage | V | 400/230 |
| Rate Current | A | 43.3 |
| Fuel Tank Capacity | L | 60 |
| Dimension For Open-type Genset | mm | 1460 X 750 X 1200 |
| Weight For Open-type Genset | kg | 762 |
| Dimension For Soundproof Genset | mm | 2050 X 900 X 1150 |
| Weight For Soundproof Generator | kg | 1050 |
| Noise Level for Soundproof Generator at 7M | dBA | 72 |
| Battery for Starting | Two of Free Maintenance Battery | |
| Engine Specification | ||
| Engine Manufacturer | Perkins Engines Company Limited | |
| Engine Brand | Perkins | |
| Engine Model | 1103A-33G | |
| No. of Cylinder | 3 Cylinder in line | |
| Aspiration | Naturally Aspirated | |
| Governor | Electric | |
| Engine Max. Output Power | kW | 31 |
| Displacement | L | 3.3 |
| Compression Ratio | 19.5 : 1 | |
| Starting Voltage | V | 12 |
| Bore | mm | 105 |
| Stroke | mm | 127 |
| Lubrication Oil Capacity | L | 7.8 |
| Intake Air Flow | M3/Min | 2.16 |
| Fuel Consumption at 100% Load | L/H | 7.1 |
| Alternator Specification | ||
| Alternator Model | S0L2-P | |
| Alternator Brand | Stamford | |
| Rate Output | kVA | 30 |
| Frequency | Hz | 50Hz |
| Altitude | M | ≤1000 |
| Insulation | Class H | |
| Phase | 3 Phase | |
| Working Temperature without power decrease | ≤40℃ | |
| Working Altitude without power decrease | ≤1000m | |
| Automatic Voltage Regulation | SX460 | |
| Protection Grade | IP23 | |
| Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
| Control Panel Specification | ||
| Controller Brand | Smartgen | |
| Controller Model | HGM6120 | |
| Breaker Brand | Delixi | |
| Breaker Capacity (A) | 63 | |
| Battery Charger | Smartgen Model BAC06A | |
| Emergency Stop Button | Supply | |
| Automatic Mains Fail (AMF) | Supply | |
| Fuel Level | Supply | |
| Automatic Transfer Switch | ATS as optional part | |
| The control panel supply the full protection with alarm and shutdown of the diesel generator include Start-up fault (generator set shutdown), High coolant temperature (alarm and generator set shutdown), Low oil pressure (alarm and generator set shutdown), Low fuel level (alarm), Low cooling fluid level alarm (as optional), Overload (alarm and generator set shutdown), Battery voltage high (alarm). | ||
| Optional controller: Each model of Deepsea, Smartgen, ComAp brand controller. | ||
The 30kVA Perkins generator set with Stamford alternator is widely used for:
lResidential backup power
lSmall offices and commercial buildings
lTelecom base stations
lFarms and agricultural facilities
lSmall industrial workshops
lConstruction site temporary power
Q1: Is this generator suitable for continuous (prime) power use?
A1: Yes. The Perkins 1103A-33G engine is designed for both prime and standby applications, providing stable output during extended operation with proper maintenance.
Q2: Why choose a Stamford alternator?
A2: Stamford alternators are globally recognized for voltage stability, durability, and high-quality manufacturing. They are especially suitable for powering sensitive equipment and ensuring smooth electrical performance.
Q3: Can the generator start automatically during a power outage?
A3: Yes. When equipped with an ATS (Automatic Transfer Switch), the generator can automatically start and supply power immediately after grid failure.
Q4: What maintenance is required?
A4: Routine maintenance includes oil changes, filter replacement, and inspection of cooling and electrical systems. The generator’s layout allows easy access for fast and efficient servicing.
Q5: What warranty does Hosem Power provide?
A5: Hosem Power offers a one-year or 1,000 running hours warranty (whichever comes first), covering manufacturing defects. Free replacement parts are provided during the warranty period.