logo

60kVA Diesel Generator Set Powered by Perkins Engine for Backup & Prime Power

1 Set
MOQ
60kVA Diesel Generator Set Powered by Perkins Engine for Backup & Prime Power
Features Gallery Product Description Request A Quote
Features
Specifications
Model: A-P66S
Max. Power: 52.8kW / 66kVA
Engine Brand: Perkins
Rate Power: 48kW / 60kVA
Engine Model: 1103A-33TG2
Frequency: 50Hz
Alternator Brand: Stamford
Rate Voltage: 400/230V
Alternator Model: S1L2-Y
Rate Current: 86.6 A
Highlight:

60kVA Perkins diesel generator

,

Perkins generator set for backup power

,

Prime power diesel generator set

Basic Infomation
Place of Origin: China
Brand Name: Hosem
Certification: CE/ ISO
Model Number: A-P66S
Payment & Shipping Terms
Packaging Details: Plastic films or ply-wood
Delivery Time: 30 days
Payment Terms: L/C, T/T
Supply Ability: 1000 Set / Months
Product Description

60kVA Diesel Generator Set Powered by Perkins Engine for Backup & Prime Power

 

The 60kVA Diesel Generator Set powered by a reliable Perkins engine is designed to provide stable and dependable electricity for both backup and prime power applications. With a proven diesel engine, efficient power generation system, and durable construction, it is a practical choice for businesses and projects that cannot afford unexpected power interruptions.

 

Whether it is used as an emergency power source during grid outages or as a primary power supply in areas with limited grid access, this 60kVA generator set delivers consistent performance under changing load conditions. Its combination of reliable engine technology, straightforward maintenance, and flexible configuration makes it suitable for a wide range of commercial, industrial, and infrastructure projects.

 

Why Choose This 60kVA Perkins Generator?

 

Reliable Perkins Engine

 

The Perkins engine provides dependable power generation with strong load response and proven durability. It is designed to support demanding operating conditions while helping users maintain predictable operating costs.

 

Flexible Backup & Prime Power

 

This generator is suitable for two common power requirements:

  • Backup Power – Automatically or manually provides electricity when the utility grid fails.
  • Prime Power – Supplies regular electricity for locations where grid power is unavailable, unreliable, or insufficient.
  • Project Power – Provides temporary electricity for construction, infrastructure, and field operations.

 

Stable Power for Different Loads

 

The generator set can supply power to a variety of electrical equipment, including lighting, pumps, motors, HVAC systems, workshop equipment, and commercial facilities. Proper generator sizing according to the actual starting and running loads helps ensure reliable operation.

 

Practical Maintenance Design

 

Routine service is an important part of generator ownership. The practical configuration of the generator allows technicians to perform regular inspections, oil and filter changes, cooling-system checks, and other maintenance work efficiently, helping reduce unnecessary downtime.

 

Built for Long-Term Operation

 

From the engine and alternator to the base frame and control system, the generator set is designed for dependable operation over an extended service life. Factory assembly and testing help ensure that the unit is ready for installation and operation after delivery.

 

Applications – Where Can a 60kVA Generator Be Used?

 

The 60kVA Perkins diesel generator is suitable for a variety of applications where reliable electricity is essential.

 

  • Commercial Buildings

It can provide backup power for offices, retail stores, restaurants, and other commercial facilities, helping keep lighting, security systems, computers, and essential equipment running during blackouts.

 

  • Construction & Infrastructure Projects

For construction sites without a stable grid connection, the generator can power tools, pumps, lighting, welding equipment, and temporary site facilities.

 

  • Industrial Workshops

Small factories and workshops can use the generator as standby or prime power for production equipment, ventilation systems, pumps, and other electrical loads.

 

  • Farms & Remote Locations

It is also suitable for agricultural operations, warehouses, remote facilities, and other locations where access to reliable utility power is limited.

 

  • Emergency Backup Systems

For businesses that need to protect critical operations from unexpected outages, the 60kVA generator can serve as a dependable emergency power source.

 

Specification of 60kVA Diesel Generator Set Powered by Perkins Engine

 

Generator Set Specification
Model A-P66S
Max. Power kVA 66
kW 52.8
Rate Power kVA 60
kW 48
Frequency Hz 50
Rate Voltage V 400/230
Rate Current A 86.6
Fuel Tank Capacity L 80
Dimension For Open-type Genset mm 1660 X 750 X 1200
Weight For Open-type Genset kg 890
Dimension For Soundproof Genset mm 2300 X 900 X 1250
Weight For Soundproof Generator kg 1426
Noise Level for Soundproof Generator at 7M dBA 72
Battery for Starting Two of Free Maintenance Battery

 

Engine Specification
Engine Manufacturer Perkins Engines Company Limited
Engine Brand Perkins
Engine Model 1103A-33TG2
No. of Cylinder 3 Cylinder in line
Aspiration Turbocharged
Governor Electric
Engine Max. Output Power kW 60.5
Displacement L 3.3
Compression Ratio 17.25 : 1
Starting Voltage V 12
Bore mm 105
Stroke mm 127
Lubrication Oil Capacity L 7.8
Intake Air Flow M3/Min 3.8
Fuel Consumption at 100% Load L/H 13.9

 

Alternator Specification
Alternator Manufacturer Cummins Generator Technologies
Alternator Model S1L2-Y
Alternator Brand Stamford
Rate Output kVA 60
Frequency Hz 50Hz
Altitude M 1000
Insulation Class H
Phase 3 Phase
Working Temperature without power decrease ≤40℃
Working Altitude without power decrease ≤1000m
Automatic Voltage Regulation SX440
Protection Grade IP23
Alternator for optional Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional

 

Control Panel Specification
Controller Brand Deepsea
Controller Model DSE7320
Breaker Brand Delixi
Breaker Capacity (A) 125
Battery Charger Smartgen Model BAC06A
Emergency Stop Button Supply
Automatic Mains Fail (AMF) Supply
Fuel Level Supply
Automatic Transfer Switch ATS as optional part
The control panel supply the full protection with alarm and shutdown of the diesel generator include Start-up fault (generator set shutdown), High coolant temperature (alarm and generator set shutdown), Low oil pressure (alarm and generator set shutdown), Low fuel level (alarm), Low cooling fluid level alarm (as optional), Overload (alarm and generator set shutdown), Battery voltage high (alarm).
Optional controller: Each model of Deepsea, Smartgen, ComAp brand controller.

 

60kVA Diesel Generator Set Powered by Perkins Engine for Backup & Prime Power

 

A Practical Power Solution from Hosem Power

 

Choosing a generator is not simply about selecting a kVA rating. Fuel consumption, engine reliability, operating conditions, load characteristics, maintenance requirements, and future power demand all affect the long-term value of a generator set.

 

The 60kVA Diesel Generator Set with Perkins Engine offers a balanced solution for customers looking for dependable power without unnecessary complexity. With suitable configuration and regular maintenance, it can provide reliable electricity for everyday operations, emergency backup, or prime power requirements.

 

FAQ

 

Q1: Is a 60kVA Perkins generator suitable for both backup and prime power?

A1: Yes. This generator set can be configured for both standby backup and prime power applications. The appropriate rating should be selected according to the customer's actual load profile and operating requirements.

 

Q2: What can a 60kVA generator power?

A2: It can support various commercial and light industrial loads, such as lighting, pumps, HVAC systems, office equipment, and workshop machinery. Motor starting loads and other high-demand equipment should be considered when sizing the generator.

 

Q3: Can the 60kVA generator be equipped with an ATS?

A3: Yes. An Automatic Transfer Switch (ATS) can be added when automatic power transfer is required. When utility power fails, the ATS system can transfer the load to the generator according to the configured control logic.

 

Q4: Is the generator easy to maintain?

A4: Yes. Regular maintenance mainly includes engine oil, filters, coolant, battery, and other system inspections. Following the recommended maintenance schedule helps maintain performance and extend service life.

 

Q5: Can Hosem Power customize the generator set?

A5: Yes. Hosem Power can provide customized configurations according to project requirements, including control systems, ATS, voltage, frequency, enclosure type, and alternator options.

 

Get Reliable 60kVA Power with Hosem Power

 

Need a 60kVA Perkins diesel generator for backup or prime power?

Hosem Power can help you select a configuration based on your load requirements, installation environment, and operating conditions.

 

👉 Get Quote today for a customized generator solution and competitive pricing.

👉 Explore More Perkins Generator Sets to find the right power range for your project.

Recommended Products
Get in touch with us
Contact Person : Mr. Edward Ye
Tel : 86-15959182792
Fax : 86-591-86397381
Characters Remaining(20/3000)