The 60kVA Diesel Generator Set powered by a reliable Perkins engine is designed to provide stable and dependable electricity for both backup and prime power applications. With a proven diesel engine, efficient power generation system, and durable construction, it is a practical choice for businesses and projects that cannot afford unexpected power interruptions.
Whether it is used as an emergency power source during grid outages or as a primary power supply in areas with limited grid access, this 60kVA generator set delivers consistent performance under changing load conditions. Its combination of reliable engine technology, straightforward maintenance, and flexible configuration makes it suitable for a wide range of commercial, industrial, and infrastructure projects.
Reliable Perkins Engine
The Perkins engine provides dependable power generation with strong load response and proven durability. It is designed to support demanding operating conditions while helping users maintain predictable operating costs.
Flexible Backup & Prime Power
This generator is suitable for two common power requirements:
Stable Power for Different Loads
The generator set can supply power to a variety of electrical equipment, including lighting, pumps, motors, HVAC systems, workshop equipment, and commercial facilities. Proper generator sizing according to the actual starting and running loads helps ensure reliable operation.
Practical Maintenance Design
Routine service is an important part of generator ownership. The practical configuration of the generator allows technicians to perform regular inspections, oil and filter changes, cooling-system checks, and other maintenance work efficiently, helping reduce unnecessary downtime.
Built for Long-Term Operation
From the engine and alternator to the base frame and control system, the generator set is designed for dependable operation over an extended service life. Factory assembly and testing help ensure that the unit is ready for installation and operation after delivery.
The 60kVA Perkins diesel generator is suitable for a variety of applications where reliable electricity is essential.
It can provide backup power for offices, retail stores, restaurants, and other commercial facilities, helping keep lighting, security systems, computers, and essential equipment running during blackouts.
For construction sites without a stable grid connection, the generator can power tools, pumps, lighting, welding equipment, and temporary site facilities.
Small factories and workshops can use the generator as standby or prime power for production equipment, ventilation systems, pumps, and other electrical loads.
It is also suitable for agricultural operations, warehouses, remote facilities, and other locations where access to reliable utility power is limited.
For businesses that need to protect critical operations from unexpected outages, the 60kVA generator can serve as a dependable emergency power source.
| Generator Set Specification | ||
| Model | A-P66S | |
| Max. Power | kVA | 66 |
| kW | 52.8 | |
| Rate Power | kVA | 60 |
| kW | 48 | |
| Frequency | Hz | 50 |
| Rate Voltage | V | 400/230 |
| Rate Current | A | 86.6 |
| Fuel Tank Capacity | L | 80 |
| Dimension For Open-type Genset | mm | 1660 X 750 X 1200 |
| Weight For Open-type Genset | kg | 890 |
| Dimension For Soundproof Genset | mm | 2300 X 900 X 1250 |
| Weight For Soundproof Generator | kg | 1426 |
| Noise Level for Soundproof Generator at 7M | dBA | 72 |
| Battery for Starting | Two of Free Maintenance Battery | |
| Engine Specification | ||
| Engine Manufacturer | Perkins Engines Company Limited | |
| Engine Brand | Perkins | |
| Engine Model | 1103A-33TG2 | |
| No. of Cylinder | 3 Cylinder in line | |
| Aspiration | Turbocharged | |
| Governor | Electric | |
| Engine Max. Output Power | kW | 60.5 |
| Displacement | L | 3.3 |
| Compression Ratio | 17.25 : 1 | |
| Starting Voltage | V | 12 |
| Bore | mm | 105 |
| Stroke | mm | 127 |
| Lubrication Oil Capacity | L | 7.8 |
| Intake Air Flow | M3/Min | 3.8 |
| Fuel Consumption at 100% Load | L/H | 13.9 |
| Alternator Specification | ||
| Alternator Manufacturer | Cummins Generator Technologies | |
| Alternator Model | S1L2-Y | |
| Alternator Brand | Stamford | |
| Rate Output | kVA | 60 |
| Frequency | Hz | 50Hz |
| Altitude | M | ≤1000 |
| Insulation | Class H | |
| Phase | 3 Phase | |
| Working Temperature without power decrease | ≤40℃ | |
| Working Altitude without power decrease | ≤1000m | |
| Automatic Voltage Regulation | SX440 | |
| Protection Grade | IP23 | |
| Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
| Control Panel Specification | ||
| Controller Brand | Deepsea | |
| Controller Model | DSE7320 | |
| Breaker Brand | Delixi | |
| Breaker Capacity (A) | 125 | |
| Battery Charger | Smartgen Model BAC06A | |
| Emergency Stop Button | Supply | |
| Automatic Mains Fail (AMF) | Supply | |
| Fuel Level | Supply | |
| Automatic Transfer Switch | ATS as optional part | |
| The control panel supply the full protection with alarm and shutdown of the diesel generator include Start-up fault (generator set shutdown), High coolant temperature (alarm and generator set shutdown), Low oil pressure (alarm and generator set shutdown), Low fuel level (alarm), Low cooling fluid level alarm (as optional), Overload (alarm and generator set shutdown), Battery voltage high (alarm). | ||
| Optional controller: Each model of Deepsea, Smartgen, ComAp brand controller. | ||
![]()
Choosing a generator is not simply about selecting a kVA rating. Fuel consumption, engine reliability, operating conditions, load characteristics, maintenance requirements, and future power demand all affect the long-term value of a generator set.
The 60kVA Diesel Generator Set with Perkins Engine offers a balanced solution for customers looking for dependable power without unnecessary complexity. With suitable configuration and regular maintenance, it can provide reliable electricity for everyday operations, emergency backup, or prime power requirements.
Q1: Is a 60kVA Perkins generator suitable for both backup and prime power?
A1: Yes. This generator set can be configured for both standby backup and prime power applications. The appropriate rating should be selected according to the customer's actual load profile and operating requirements.
Q2: What can a 60kVA generator power?
A2: It can support various commercial and light industrial loads, such as lighting, pumps, HVAC systems, office equipment, and workshop machinery. Motor starting loads and other high-demand equipment should be considered when sizing the generator.
Q3: Can the 60kVA generator be equipped with an ATS?
A3: Yes. An Automatic Transfer Switch (ATS) can be added when automatic power transfer is required. When utility power fails, the ATS system can transfer the load to the generator according to the configured control logic.
Q4: Is the generator easy to maintain?
A4: Yes. Regular maintenance mainly includes engine oil, filters, coolant, battery, and other system inspections. Following the recommended maintenance schedule helps maintain performance and extend service life.
Q5: Can Hosem Power customize the generator set?
A5: Yes. Hosem Power can provide customized configurations according to project requirements, including control systems, ATS, voltage, frequency, enclosure type, and alternator options.
Need a 60kVA Perkins diesel generator for backup or prime power?
👉 Get Quote today for a customized generator solution and competitive pricing.
👉 Explore More Perkins Generator Sets to find the right power range for your project.