Generator Standard Compose:
Learn about Cummins series product: https://www.hosempower.com/open-type-diesel-generator-powered-by-cummins_p2.html
Generator Set Specification | ||
Model | A-C28H | |
Max. Power | kVA | 28 |
kW | 22.4 | |
Rate Power | kVA | 25 |
kW | 20 | |
Frequency | Hz | 60 |
Rate Voltage | V | 220/127 |
Rate Current | A | 65.6 |
Dimension For Open-type Genset | mm | 1750 X 750 X 1050 |
Weight For Open-type Genset | kg | 880 |
Dimension For Soundproof Genset | mm | 2300 X 900 X 1250 |
Weight For Soundproof Generator | kg | 1200 |
Engine Specification | ||
Engine Manufacturer | Dongfeng Cummins Engine Co., Ltd. | |
Engine Brand | Cummins | |
Engine Model | 4B3.9-G2 | |
No. of Cylinder | 4 Cylinder in line | |
Aspiration | Naturay Aspirated | |
Governor | Electric | |
Engine Max. Output Power | kW | 33 |
Displacement | L | 3.9 |
Starting Voltage | V | 24 |
Bore | mm | 102 |
Stroke | mm | 120 |
Lubrication Oil Capacity | L | 11 |
Alternator Specification | ||
Alternator Manufacturer | Cummins Generator Technologies | |
Alternator Model | PI 144D | |
Alternator Brand | Stamford | |
Rate Output | kVA | 25 |
Frequency | Hz | 60Hz |
Altitude | M | ≤1000 |
Insulation | Class H | |
Voltage Regulation | AVR Model SX460 | |
Protection Grade | IP23 | |
Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
Why Choose Hosem Power Generator?
Reasons1: We are More Professional
Most members of Hosem Power have more than 10 years of experience in the generator area, Our mechanical engineers, electrical engineers have more than 20 years of experience in the generator ara. We are always ready to serve to your needs.
Reasons2: Outstanding Quality
Our advantage lies in:
1. Good shock absorption performance: Optimal design of shock absorption system based on computer dynamic simulation.
2. Advanced control system: Full monitoring system control strategy found on reliability design.
3. Low noise: Tailor custom-engineered exhaust silencer system for each set.
4. Green environmental protection: Diesel generator set combined energy-saving and low emission in one.
Reasons3: Strictly QC Before EX-Factory.
Each and every unit is strictly factory tested before shipment.
1) Parts faults testing
2) Fuel tank pressure testing
3) Bolt tightening torque testing
4) Painting thickness testing
5) Voltage bearing and insulation testing
6) Noise testing
7) Loading Testing: 25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection.